MX33 10~40k

MX33 10~40k

The MX33 UPS is a 3-phase In/Out online double conversion UPS available from 10kVA to 40kVA with an output power factor 1. It is designed to provide ultimate performance in power protection and redundancy for critical systems requiring high power availability. The MX33 series has USB and RS-232 communication ports as standard, with a built-in intelligent slot for optional protocol converters (e.g. SNMP…). The MX33 Series is the best solution for different applications: server rooms, data centers, healthcare sector, financial applications...

3-phase In/3-phase Out
True Online Double Conversion Design
Pure Sine Wave Output
Fully Digitized Microprocessor Control
DSP Technology
Output Power Factor 1
Active Input Power Factor Correction (PFC 0.99)
50/60 Hz Frequency Converter
Wide Input Voltage Range
Built in Automatic Bypass
Generator Compatible
N+X Parallel Redundancy Configuration*

Emergency Power Off Function (EPO)
Cold Start Function (DC Power On)
Advanced Battery Management (ABM Technology)
Automatic Diagnostics & Battery Check
High Overload Capability and Enhanced Short Circuit Protection
Eco Mode For Energy Saving
Isolation Transformer*
Programmable Power Management Outlets
Multi-Function LCD Display
Software Monitoring and Control
Smart RS-232/USB Communication Port
SNMP/AS-400 Communication Slots*

*Optional Features

Specifications

Model MX 10K 33
Input
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
10000VA
380V, 400V, 415V (selectable), 3Φ4Wires
40~70Hz
176-276 VAC at 100% load, 110-300 VAC at 50% load
>99%
<3%
Output
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
10000W

380V, 400V, 415V +/-1% (selectable output voltage), 3Ø4Wires

50/60 Hz +/-1%
0 ms
Online double conversion design
Pure Sinewave
≤1% (linear load), ≤4% (non linear load)
3:1
Efficiency
AC Mode
Battery Mode
96.5%
95.5%
Protection
Overload Protection
Short Circuit Protection
110% for 60min, 125% for 10min, 150% for 1min, >150% for 400ms
UPS output cut off immediately using input fuse/circuit breaker protection
System Display
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
Alarm
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
Battery
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
12V 9Ah 
9 hours to 90% capacity
1A ~ 12A (adjustable)
(10+10) x1 string
10~15 min depending on load
Communication
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
Physical
W x D x H mm
Net Weight Kgs(lbs)
250 x 630 x 826
124 (273.3lbs)
Environment
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<60dBA at 1 Meter
Standards & Certifications
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • MX 1~10k

    MX 1~10k

    True on-line double conversion...more
  • MX31 10~20k

    MX31 10~20k

    True on-line double conversion...more
  • MXRM31 10~20k

    MXRM31 10~20k

    True double-conversion DSP technology...more
  • MXL31 10~20k

    MXL31 10~20k

    Long autonomy UPS True online double...more
  • MXLRM31 10~20k

    MXLRM31 10~20k

    Long autonomy UPS True online double...more
  • MXL33 10~60k

    MXL33 10~60k

    Three phase, true on-line double...more