The MX UPS is an online double conversion UPS available from 1kVA to 10kVA with an output power factor 1. It is designed to provide continuous utility power protection for critical system installation. The MX series has USB and RS-232 communication ports as standard, with a built-in intelligent slot for optional protocol converters (e.g. SNMP…). The MX Series is the best solution for different applications: data centers, servers and networking devices, control systems, video surveillance systems...

True Online Double Conversion Design
Pure Sine Wave Output
Fully Digitized Microprocessor Control
DSP Technology
Output Power Factor 1
Active Input Power Factor Correction (PFC 0.99)
50/60 Hz Frequency Converter
Wide Input Voltage Range
Built in Automatic Bypass
Generator Compatible
N+X Parallel Redundancy Configuration*
Emergency Power Off Function (EPO)

 

Cold Start Function (DC Power On)
Advanced Battery Management (ABM Technology)
Automatic Diagnostics & Battery Check
High Overload Capability and Enhanced Short Circuit Protection
Eco Mode For Energy Saving
Isolation Transformer*
Programmable Power Management Outlets
Multi-Function LCD Display
Software Monitoring and Control
Smart RS-232/USB Communication Port
SNMP/AS-400 Communication Slots*

*Optional Features

Specifications

Model MX 1k
Input
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
1000VA
220V, 230V, 240V, 1Ø 2Wires
40Hz~70Hz
160-300 VAC at 100% load, 110-300 VAC at 50% load
>99%
≤3%
Ouput
Output Power with cosφ=1
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
1000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1Hz
0 ms
Online double conversion design
Pure Sinewave
≤2% (linear load), ≤4% (non linear load)
3:1
Efficiency
AC Mode
Battery Mode
95%
93%
Protection
Overload Protection
Short Circuit Protection
110% for 10min, 130% for 1min, >130% for 3sec
UPS output cut off immediately using input fuse/circuit breaker protection
System Display
LCD indicators
UPS status, load level, battery level, input/output voltage, discharge time and fault indicators
Alarm
Battery mode
Low battery
Overload
Fault
Sounding every 4 second
Sounding every second
Sounding twice every second
Continuously sounding
Battery
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Back up time(1/2 Load)
12V 7Ah
4 hours to 90% capacity
1.5A
36 VDC
10~15 min depending on load
Communication
USB, RS-232, AS-400**
SNMP**
Compatibility
Interface with power management software
Power Management from SNMP manager and web browser
Supports Windows family, Linux, Unix and Mac
Physical
Dimension, WxDxH mm
Net Weight Kgs(lbs)
145 X 397 X 220
12.5 (27.5lbs)
Environment
Ambient operation
Audible noise
Maximum elevation at 1000m, 0 to 40°C, 20 to 95% humidity (non-condensing)
<50dBA at 1 Meter
Standards & Certifications
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
* NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • MX31 10~20k

    MX31 10~20k

    True on-line double conversion...more
  • MXRM31 10~20k

    MXRM31 10~20k

    True double-conversion DSP technology...more
  • MXL31 10~20k

    MXL31 10~20k

    Long autonomy UPS True online double...more
  • MXLRM31 10~20k

    MXLRM31 10~20k

    Long autonomy UPS True online double...more
  • MX33 10~40k

    MX33 10~40k

    Three phase, true on-line double...more
  • MXL33 10~60k

    MXL33 10~60k

    Three phase, true on-line double...more